BDI-2008 series_Push-Pull Indicator & Controller
-
Analog Input and A/D Conversion::
-
Type:BDI-2008
-
Input Sensitivity:0.3u/V/D
-
ZERO Adjustment Range:0mV ~24 mV
-
Max. Load Cell Excitation:±32mV
-
Load Cell Excitation:10V
-
Non-Linearity:±0.01 % F.S.
-
A/D Conversion Method:ΔΣ
-
A/D Resolution:= 1/1,000,000
-
A/D Conversion Rate:Approx. 120 Times / Sec.
-
Main Display (Green Tube):7-segment '7-digit display, VFD screen with q 13mm character size, display the weight.
-
Minimum Division:X1' X2' X5' X10' X20' X50
-
Maximum Display:± 500450
-
General::
-
Type:BDI-2008
-
Power Requirements:AC 220Vn±10% ' 50/60 Hz. Approx. 17 VA
-
Net weight:Approx. 3.2 kg (7.054 Ib)
-
Operation Temperature:-10˚ C ~45˚ C
-
Maximum Humidity:85% (non-condensing)
-
Physical Dimensions:240 (D) X 190 (W) X 104 (H) mm
-
Standard::
-
Current Loop:20mA
-
Geberal::
-
OP-01:I/O Interface
-
OP-02:Serial Interface RS-232 or RS-422/485
-
OP-03:Printer Interface (Include Date and Time)
-
OP-04:Parallel BCD output
-
OP-05:Analog Output 4~20mV
-
OP-05:Analog Output 0~10V
Description
Push-Pull (Compression-Tensile) Measuring Use.
2 sets of Load Cell Sensor with individual capacity.
-32mV ~ +32mV load Cell Input Voltage.
Fully Digital Calibration.
Features:
• BDI-2008 connected to 2 sets of load cell sensors
with two separate capacity and calibration (SRAM will
store two set of parameter).
• 1/10,000 display resolution, A/D conversion rate 120
times/sec.
• 5 testing modes for test: Manual Hold, Hold positive peak,
Hold negative peak, Hold both positive and negative peak and
Burn-in test.
• “Watchdog” virtually eliminates malfunctions that associated with computerized equipment or software failure
• Full digital Calibration makes setting ZERO and SPAN Calibration an easy task.
• Drives up to 8 (350Ω) parallel connecting load cells or a scale structure of 2 sets of load cells [ each set with 4
(350Ω) load cells].
• 8k bytes SRAM with Li-battery backup. Information will not disappear even power failure.
• The settings of function and weighing parameters are all stored in the EEPROM, with storage duration over 40
years.
• Important values and parameters can have storage backup.
• Users can adjust the intensity of digits filter to avoid mechanical vibration that caused by external
environments to achieve high-speed and accurate measurement.
• Control Inputs: ZERO Input, START/STOP, select P1/P2 and Print.
• Control Outputs: ZERO band output, HI output, LO output, FR output, RUN output and ERROR.
• Standard Serial Output (20mA Current Lop) for remote display.
• Optional printer interface can automatically print or output data includes date and time.
with two separate capacity and calibration (SRAM will
store two set of parameter).
• 1/10,000 display resolution, A/D conversion rate 120
times/sec.
• 5 testing modes for test: Manual Hold, Hold positive peak,
Hold negative peak, Hold both positive and negative peak and
Burn-in test.
• “Watchdog” virtually eliminates malfunctions that associated with computerized equipment or software failure
• Full digital Calibration makes setting ZERO and SPAN Calibration an easy task.
• Drives up to 8 (350Ω) parallel connecting load cells or a scale structure of 2 sets of load cells [ each set with 4
(350Ω) load cells].
• 8k bytes SRAM with Li-battery backup. Information will not disappear even power failure.
• The settings of function and weighing parameters are all stored in the EEPROM, with storage duration over 40
years.
• Important values and parameters can have storage backup.
• Users can adjust the intensity of digits filter to avoid mechanical vibration that caused by external
environments to achieve high-speed and accurate measurement.
• Control Inputs: ZERO Input, START/STOP, select P1/P2 and Print.
• Control Outputs: ZERO band output, HI output, LO output, FR output, RUN output and ERROR.
• Standard Serial Output (20mA Current Lop) for remote display.
• Optional printer interface can automatically print or output data includes date and time.