BDI-2008 series_Push-Pull Indicator & Controller

  • Analog Input and A/D Conversion:
    :
  • Type:
    BDI-2008
  • Input Sensitivity:
    0.3u/V/D
  • ZERO Adjustment Range:
    0mV ~24 mV
  • Max. Load Cell Excitation:
    ±32mV
  • Load Cell Excitation:
    10V
  • Non-Linearity:
    ±0.01 % F.S.
  • A/D Conversion Method:
    ΔΣ
  • A/D Resolution:
    = 1/1,000,000
  • A/D Conversion Rate:
    Approx. 120 Times / Sec.
  • Main Display (Green Tube):
    7-segment '7-digit display, VFD screen with q 13mm character size, display the weight.
  • Minimum Division:
    X1' X2' X5' X10' X20' X50
  • Maximum Display:
    ± 500450
  • General:
    :
  • Type:
    BDI-2008
  • Power Requirements:
    AC 220Vn±10% ' 50/60 Hz. Approx. 17 VA
  • Net weight:
    Approx. 3.2 kg (7.054 Ib)
  • Operation Temperature:
    -10˚ C ~45˚ C
  • Maximum Humidity:
    85% (non-condensing)
  • Physical Dimensions:
    240 (D) X 190 (W) X 104 (H) mm
  • Standard:
    :
  • Current Loop:
    20mA
  • Geberal:
    :
  • OP-01:
    I/O Interface
  • OP-02:
    Serial Interface RS-232 or RS-422/485
  • OP-03:
    Printer Interface (Include Date and Time)
  • OP-04:
    Parallel BCD output
  • OP-05:
    Analog Output 4~20mV
  • OP-05:
    Analog Output 0~10V

Description

Push-Pull (Compression-Tensile) Measuring Use.

2 sets of Load Cell Sensor with individual capacity.

-32mV ~ +32mV load Cell Input Voltage.

Fully Digital Calibration.

Features:

• BDI-2008 connected to 2 sets of load cell sensors
with two separate capacity and calibration (SRAM will
store two set of parameter).
• 1/10,000 display resolution, A/D conversion rate 120
times/sec.
• 5 testing modes for test: Manual Hold, Hold positive peak,
Hold negative peak, Hold both positive and negative peak and
Burn-in test.
• “Watchdog” virtually eliminates malfunctions that associated with computerized equipment or software failure
• Full digital Calibration makes setting ZERO and SPAN Calibration an easy task.
• Drives up to 8 (350Ω) parallel connecting load cells or a scale structure of 2 sets of load cells [ each set with 4
(350Ω) load cells].
• 8k bytes SRAM with Li-battery backup. Information will not disappear even power failure.
• The settings of function and weighing parameters are all stored in the EEPROM, with storage duration over 40
years.
• Important values and parameters can have storage backup.
• Users can adjust the intensity of digits filter to avoid mechanical vibration that caused by external
environments to achieve high-speed and accurate measurement.
• Control Inputs: ZERO Input, START/STOP, select P1/P2 and Print.
• Control Outputs: ZERO band output, HI output, LO output, FR output, RUN output and ERROR.
• Standard Serial Output (20mA Current Lop) for remote display.
• Optional printer interface can automatically print or output data includes date and time.


You may also like

  • 1705 Ga Series_Weighing Indicator
  • SEK Series - Check Weigher
  • AD-4401 Series_High Performance Weighing / Batching Indicator
  • WS-630 series_High Resolution Weighing Scale